Test workplace fire alarms

Issue 6 2021 Fire & Safety

Office and building managers have a responsibility to ensure that staff members are properly protected by a fire alarm system that is regularly tested and working in the way it should.

These systems require constant tests, maintenance and care, in the same way that any home security system should be tested. “In fact, we recommend that these workplace systems be tested even more frequently than a home system would be checked. There is the obvious aspect that you have more foot traffic and more equipment at your place of work than at home, which requires more frequent testing of this important safety system,” says Andrew Worthington, general manager: Fidelity Fire Solutions, a division of Fidelity Services Group.

“A number of regulations govern the industry and they need to be adhered to at all times. The SANS codes in particular are clear about the legal requirements that apply.”

The codes state that:

• SANS 10400:2010 T1(1) … any building shall be so designed, constructed and equipped that in case of fire: (e) Adequate means of access and equipment for detecting, fighting, controlling and extinguishing such fire, is provided.

• T2 meanwhile warns that any owner of any building who fails to maintain any other provision made to satisfy the requirements of sub-regulation (T)1(1)(e), shall be guilty of an offence.

• SANS 10139:2012 Part 12 is about maintenance, servicing and routine testing of fire alarm systems. Fire alarm systems should be visually inspected for damage or errors daily and serviced by an accredited fire alarm installer every six months to stay compliant to regulations and building insurance requirements. Services must be recorded and faults, changes and updates listed in a logbook.

“Fire safety is a long-term investment that must be carefully planned to ensure the business’s continuity and ultimately to properly protect both people and property,” says Worthington.

There are basic steps that any company or workplace can take today, to help protect staff and equipment from fires. Putting the proper preventative measures in place and generating a general staff awareness of fire risks and how to prevent these risks is a good first step to take.

“We also recommend that office and building managers carefully study the relevant occupational health regulations and legislation that is relevant to their industry as these might have additional measures that should be put in place,” says Worthington.

Other dos and don’ts to consider are:

• Do test the system regularly. Keep a careful log of when the system was tested and by whom, as well as which parts of the system were tested (including the test outcome).

• Do make sure your staff know what to do when an alarm is triggered. Every workplace should have an evacuation plan in place, which is shared with team members and practised on a regular basis.

• Do follow up on test errors. If your test showed a faulty sensor or any other technical problems, contact your service provider as a matter of urgency to have these addressed.

• Do allocate more than one team member to your fire system’s testing routines. There is a risk involved in having only one person who knows how to properly test the fire alarm system.

• Do test the fire alarms during normal office hours. Yes, this will be disruptive to normal operations but that is the intended purpose behind a fire alarm system. Testing it outside of office hours when there are no staff members around, defeats the purpose.

• Do connect the fire alarm system to your monitoring system. If you haven’t asked your armed response company if they can also monitor your fire alarm system, then ask them how you can set this up.

• Don’t confuse testing the fire alarm with regular system maintenance or scheduled visits by your service provider. The test is intended to determine the system’s ability to register a fire and to alert you, while a maintenance visit will be done by your service provider who will focus on technical work or upgrades that might be required.

• Don’t test the same part of your system every time. If possible, look at testing a different sensor or aspect of the system each time a test is conducted.

• Don’t ever ignore potential workplace fire hazards. This includes overloaded power plugs, dust on your fire sensors, or the actions of staff members that can lead to fires such as cigarette butts dumped in trash cans.

References

https://www.w-fp.co.uk/top-5-fire-alarm-test-dos-and-donts/

https://tamarsecurity.co.uk/how-often-should-you-test-your-fire-alarm/

https://www.saqccfire.co.za/about.html

https://www.atotalsolution.com/blog/your-guide-to-regular-fire-alarm-testing-and-maintenance/

For more information contact Fidelity Services Group, [email protected], www.fidelity-services.com / www.adt.co.za




Share this article:
Share via emailShare via LinkedInPrint this page



Further reading:

Enhancing safety in battery energy storage systems
Technoswitch Fire Detection & Suppression Products & Solutions Fire & Safety
The calibration-free Combustible Gas & VOC Sensor by Technoswitch can be configured to detect various flammable gases, including electrolyte vapours (VOC) and hydrogen, and is an indispensable tool for ensuring the safety of Li-ion battery storage systems.

Read more...
ESPRIT intelligent fire panel range
Technoswitch Fire Detection & Suppression Products & Solutions Fire & Safety
Technoswitch recently added the EN54-approved ESPRIT intelligent control panel range to its product portfolio to complement the existing TC5000 intelligent control panel range, aimed at small and medium sites that require a cost-effective, networkable fire alarm system.

Read more...
Standards for fire detection
Fire & Safety
Nick Collins discusses standards for commissioning and handing over a fire project once the installation is complete.

Read more...
Standards for fire detection
SAQCC (Fire) Fire & Safety Associations
In the second article from SAQCC, Nick Collins focuses on SANS 10139, which is generally regarded as the ‘Book of Knowledge’ for any fire detection installer, commissioner and designer.

Read more...
Technology driving fire safety at Firexpo 2025
Securex South Africa News & Events Fire & Safety
As regulations change, safety and risk officers, and building managers are hard-pressed to keep pace with the exact requirements to ensure occupant safety and wellbeing. Firexpo’s role is to provide informed choices for the market.

Read more...
The unusual chemistry of lithium-ion battery fires
SafeQuip Fire & Safety
Traditional fire extinguishers, which use agents like water, foam, or dry chemicals, may not be suitable for lithium-ion battery fires due to the unique challenges posed by the high-energy density of these batteries.

Read more...
Saving lives with fire safety technology
Fire & Safety News & Events
The fire protection landscape is evolving swiftly, fuelled by technological advancements designed to improve safety and efficiency in fire detection, control, and suppression. These innovations transform traditional methods and establish new safety standards in residential and commercial spaces.

Read more...
Standards for fire detection
SAQCC (Fire) Fire & Safety
In the second article from SAQCC, Nick Collins focuses on SANS 10139, which is generally regarded as the “Book of Knowledge” for any fire detection installer, commissioner and designer.

Read more...
Rational design is not just a tick-box exercise
Fire & Safety
Rational design is about achieving performance-driven fire safety measures through sound engineering principles. It is not just a tick-box exercise, but involves a deep understanding of fire risks and behaviour, and developing customised fire protection strategies.

Read more...
Fire detection and gas suppression systems
Masc Solutions Products & Solutions Fire & Safety
Masc Solutions is an official Fike distributor and installer in South Africa, providing comprehensive design, supply, and installation services for specialised gas fire suppression systems.

Read more...