Why you can’t ignore Category 6A anymore

August 2015 News & Events

Overview

Category 6A twisted-pair copper solutions received much attention when they first hit the market in 2005, and again when the ANSI/TIA-568-B.2-10 Category 6A standard was published in April of 2008. However, the past decade has witnessed slow adoption in the enterprise environment, especially in the LAN. Early implementations were relatively expensive due to installation, field testing and power consumption.

But times are changing. Data rates continue to climb and more devices than ever are connected to the network. Emerging applications are demanding the higher performance and faster speeds supported by Category 6A cabling. For these reasons, industry standards that previously only recommended Category 6A cabling for data centres now also recommend it for most LAN installations.

Emerging applications now demand it

We are seeing a greater need for bandwidth intensive applications that require speeds beyond 1000 Mb/s in today’s LAN. Backbone speeds in the data centre are migrating to 25, 40 and even 100 Gb/s; horizontal LANs need to keep up or risk being a bottleneck to productivity. The need to transfer larger files, such as medical imaging, high-definition streaming video, high-end graphics and surveillance video are starting to task Category 5e and Category 6 networks running 100BASE-TX and even 1000BASE-T. For example, in the healthcare environment a set of medical images for a single patient totalling 9000 MB takes about a minute to download over a 1000 Mb/s network, but only seven seconds over a 10 Gb/s network. In an emergency situation, the time difference can be critical.

Three reasons for non-adoption which are no longer valid

Physical: The first Category 6A cables were up to 50% larger than their Category 6 predecessors, but newer small-diameter Category 6A cables are only about 15% larger. This eliminates added size and weight, which impacts how many cables fit into a cable tray or conduit. Reduced bend radius also improves ease of installation, termination and handling. These improvements make Category 6A a viable, cost-effective cable option – especially in retrofit installations.

Application: Applications in the horizontal LAN have not typically required speeds beyond 1000 Mb/s (or even 100 Mb/s). Many believed that 10 Gb/s speeds would not be needed in the LAN over the life of Category 6 cable. But times have changed and now there is an increasing demand for 10GBASE-T in both the LAN and data centre markets. The growth of 10GBASE-T is largely because of the need to support fibre backbone speeds beyond 10 Gb/s, large hyperscale computing environments (25, 40 or 100 Gigabit speeds), and enterprise data centres deploying 10GBASE-T for switch-to-server connections. Category 6A cable supports 10GBASE-T up to 100 m, and operates at frequencies of up to 500 MHz – twice that of Category 6.

Financial: Installers previously had to budget more time and money to test for the new parameters, including alien attenuation crosstalk ratio far-end (AACRF), alien near-end crosstalk (ANEXT) and power sum alien crosstalk parameters (i.e. PSAACRF and PSANEXT). Today however, many of the Category 6A cost obstacles have been offset or eliminated thanks to manufacturing advancements and improvements in 10GBASE-T physical layer device (PHYs) design. Dramatic improvements to 10GBASE-T active equipment have also decreased cost and power consumption per port (1,5 to 3 Watts per port vs. 12 Watts per port for first-generation 10GBASE-T PHYs). In fact, today’s fourth generation 10GBASE-T provides a much lower price per gigabit (less than 30%) than 1000BASE-T at a power level that is quite acceptable.

Seven things to look for when choosing the right Category 6A cable

Size and weight: Controlling noise and crosstalk at higher frequencies has required Category 6A cables up to 50% larger than their Category 6 predecessors. While many available Category 6A options remain significantly larger and heavier, the newest Category 6A cables are only about 15% larger than Category 6.

Bend radius: The cable is easier to route and install. It also allows cable routing for maximum airflow within racks.

Installation complexity: Most Category 6A cables are larger because of their material: more twists in the copper pairs, larger splines separating the pairs, and thicker outer jackets. This adds up to cables that take longer to prepare and terminate. Smaller and more round cables take less time to install.

Power delivery: In a conventionally designed cable, the spline and jacket surrounding each copper pair create an insulated compartment that is prone to overheating. Newer thermal dissipation designs distribute heat around the circumference of the cable, eliminating hotspots. Some are capable of delivering up to 100 W PoE while keeping thermal rise within acceptable limits

Channel length: Some small diameter Category 6A cables may not support the full 100 m distance per channel, and need to be de-rated to less than full length. A cable that can handle the full 100 m not only provides an extra margin of performance, but supports full length LAN channels and a wider range of data centre configurations, including top-of-rack, end of-row and middle-of-row configurations.

Ground loops: When a shielded cable is terminated at both ends to a local ground and a remote ground, the ground potential difference can cause stray currents to flow in the shield and couple noise into the conductors, interfering with signals and causing transmission errors.

EMI shielding: There is no doubt that a shielded cable provides better noise immunity when grounded at both ends with a low impedance ground connection at high frequencies. The effectiveness of the shield depends on the quality and reliability of the shield termination and the quality of the local and remote ground connections. Sometimes a low impedance ground connection is difficult to achieve. Cable designs that symmetrically surround well balanced twisted pairs with a Faraday cage can provide an effective electromagnetic barrier without the need and potential drawbacks of grounding.

Belden 10GXS high-performance small diameter Category 6A cables

Belden’s advanced engineering expertise and precision manufacturing have resulted in yet another innovation – 10GXS cables.

With the small diameter and excellent mechanical and electrical characteristics, 10GXS cables offer improved space and weight savings with beyond-standards performance to meet all current and emerging applications.

For more information contact Greg Pokroy, Jaycor International, +27 (0)21 447 4247, [email protected], www.jaycor.co.za





Share this article:
Share via emailShare via LinkedInPrint this page



Further reading:

Highest increase in global cyberattacks in two years
Information Security News & Events
Check Point Global Research released new data on Q2 2024 cyber-attack trends, noting a 30% global increase in Q2 2024, with Africa experiencing the highest average weekly per organisation.

Read more...
From the editor's desk: Showtime for Securex
Technews Publishing News & Events
We have once again reached the time of year when the security industry focuses on Securex. This issue includes a short preview, with more coming online and via our special Securex Preview news briefs. ...

Read more...
Chubbsafes celebrates 190 years
Gunnebo Safe Storage Africa News & Events Security Services & Risk Management
Chubbsafes marks its 190th anniversary in 2025 and as a highlight of the anniversary celebrations it is launching the Chubbsafes 1835, a limited edition 190th-anniversary collector’s safe.

Read more...
Suprema unveils BioStar Air
Suprema neaMetrics News & Events Access Control & Identity Management Infrastructure
Suprema launches BioStar Air, the first cloud-based access control platform designed to natively support biometric authentication and feature true zero-on-premise architecture. BioStar Air simplifies deployment and scales effortlessly to secure SMBs, multi-branch companies, and mixed-use buildings.

Read more...
New law enforcement request portal
News & Events Security Services & Risk Management
inDrive launches law enforcement request portal in South Africa to support safety investigations. New portal allows authorised South African law enforcement officials to securely request user data related to safety incidents.

Read more...
Igniting standards, powering protection
Securex South Africa News & Events Fire & Safety
Fire safety is more than compliance, it is a critical commitment to protecting lives, assets, and infrastructure. At Firexpo 2025, taking place from 3 to 5 June at Gallagher Convention Centre, that commitment takes centre stage.

Read more...
The rise of AI-powered cybercrime and defence
Information Security News & Events AI & Data Analytics
Check Point Software Technologies launched its inaugural AI Security Report, offering an in-depth exploration of how cybercriminals are weaponising artificial intelligence (AI), alongside strategic insights defenders need to stay ahead.

Read more...
From the editor's desk: We’ve only just begun
Technews Publishing News & Events
The surveillance market has expanded far beyond the analogue days of just recording and/or monitoring screens. The capabilities of surveillance technology today extend to black screen monitoring with ...

Read more...
SAFPS issues SAPS impersonation scam warning
News & Events Security Services & Risk Management
The Southern African Fraud Prevention Service (SAFPS) is warning the public against a scam in which scammers pose as members of the South African Police Service (SAPS) and trick and intimidate individuals into handing over personal and financial information.

Read more...
Strong industry ties set Securex South Africa apart
News & Events Training & Education
Securex South Africa, co-located with A-OSH EXPO, Facilities Management Expo, and Firexpo, is a meeting place of minds, where leading security, safety, fire, and facilities professionals come together, backed by strong ties with the industry’s most influential bodies.

Read more...