Ensuring your electric fence is compliant

Residential Estate Security Handbook 2019 Perimeter Security, Alarms & Intruder Detection, Security Services & Risk Management

A challenge facing both existing and potentially new perimeter electric fence installations is how to economically meet the legal requirements required in clauses 4.8.2, 9.4, and 9.7 of the SANS 10222-3:2016 standards document referred to in the new Act. These clauses relate to the protection of the general public from being accidently shocked by an electric security fence.

These clauses require one to erect an expensive barrier fence in front of an electric fence to protect the general public from making inadvertent or accidental contact with the fence and thus receiving a shock. A solution to overcome this expensive option economically is to install JVA low voltage monitors along those portions of the fence-line requiring protection from the public.

Let us start by looking at the relevant clauses referred to in the Act, their interpretation, and their purpose:

9.4 Installation

Clause 9.4.1.2 states: “No electric fence shall be installed in a public area unless the first live conductor’s minimum height is 1500 mm above walking or ground level (or both) or is covered by a barrier fence from the public area with a minimum height of 1500 mm….”

Quite simply, this means that one may not have any high-powered electric fence wires below a height of 1500 mm, be it for a wall-top or free-standing electric fence and, if you do, you must have a barrier fence in front of these live wires. This is to prevent the general public, and in particular, small children, from making accidental contact with the fence and being shocked.

Clause 9.4.3.1 states, “The minimum distance between an electric fence and a building element or barrier fence (or both) shall be less than 200 mm or greater than 1000 mm.”

This means that your barrier fence has to be closer than 200 mm or further than 1000 mm away from the electric fence. Why? Simply to avoid entrapment between the electric fence and the barrier fence. One can’t fit between 200 mm away barrier fence and the electric fence or alternatively one has enough space to move between the barrier and the electric fence if it is over a metre away.

Clause 9.4.3.2 states, “The building element or barrier fence next to an electric fence (or both) shall have one dimension of the opening not greater than 150 mm.”

This means that one can use palisade fencing as the barrier fence as long as the panels of the palisade are no more than 150 mm apart. Alternatively, one can reinforce an existing palisade fence with electric wires as long as the panels are no more than 150 mm apart. Once again, the public is protected.

9.7. Barrier fences

Clause 9.7 states: “Barrier fences shall have

a) A minimum height of 1500 mm, and

b) One dimension of the opening not greater than 150 mm”.

Again, for protection. One can’t simply stretch over the barrier fence and touch the electric fence, nor can one accidently blunder into it. However, clause 4.8.2. then states, “… the minimum height of the barrier fence can be reduced to 1.2 m provided the barrier is erected more than 1.5 m from the electric fence. The barrier fence shall comply with 9.4.3.2.”

This clause effectively means that people in rural areas (farmers in particular) need not install a barrier fence next to their homestead electric security fence because the farm is ring fenced by a 1.2 m fence which is more than 1.5 m away from the electric fence. Anyone within this area is not regarded as general public and if they are there without permission they are trespassing.

How to adhere to the law

This brings us to the question of how to meet these legal requirements. There are two scenarios that need to be covered, both of which require a COC. A COC is a Certificate of Compliance that certifies that the fence meets legal requirements. The two scenarios are: a homeowner with a property which is for sale, with an existing electric fence around it, which will need to produce a COC at completion and handover; and any new security electric fence erected after 1 October 2012 will also require a COC.

In the first scenario above, one has two options: the first option is to erect a barrier fence in accordance with the legislation. This is an expensive option. A further problem encountered with many existing installations’ electric security fences is that they have been erected right on the property’s boundary, so there is no room to erect an expensive barrier fence, even if the owner wishes to do so.

In this case, the simplest solution is to reconfigure the fence so that the bottom 1500 mm is still monitored but now, by using JVA’S low voltage technology while the upper portion above 1500 mm retains its high voltage shock and monitoring ability. This option will obviously remove the deterrent shock off that portion of the fence, but it will still be monitored and will still retain a visual psychological deterrence.

When it comes to the erection of new, free-standing fences, one can simply repeat the above and power the bottom 1500 mm portion of the fence lines using a JVA ZLM4 low-voltage monitoring system and again have the top portion wired for high-voltage monitoring – a simple, economical and effective solution. One could also further improve the sensitivity of the fence by including a taught-wire monitoring system into this design.

Low-voltage compared to reduced-voltage

A question often asked is what exactly is low-voltage monitoring compared to reduced-voltage monitoring and how come this low-voltage monitoring makes the fence legal? According to Clause 3.30 of SANS 10222-3-2016: ‘High tension electric fencing – where the peak voltage of the pulsed system exceeds 50 V d.c. or a.c. (r.m.s.)”. A JVA LM4 meets this requirement by emitting a monitored pulse of less than 50 volts. By definition it is therefore not a high-tension electric fence and it is therefore completely legal.

On the other hand, reduced-voltage fencing is simply a high-powered energiser that has had its output voltage reduced by means of applying resistors and these generally operate at around 600 volts making it still a high-tension electric fence and therefore illegal.

For more information contact Ndlovu Fencing (T/A Stafix Electric Fence Centre), 0861 STAFIX (782349), [email protected], www.jvasecurity.com



Credit(s)




Share this article:
Share via emailShare via LinkedInPrint this page



Further reading:

SABRIC Annual Crime Statistics 2024
News & Events Security Services & Risk Management Residential Estate (Industry)
SABRIC has released its Annual Crime Statistics for 2024, reflecting a significant decline in financial crime losses, but also warning of the growing threat posed by artificial intelligence (AI) in fraud schemes.

Read more...
Adding AI analytics to security monitoring
SEON South Africa News & Events Perimeter Security, Alarms & Intruder Detection Residential Estate (Industry) AI & Data Analytics
SEON has announced its latest integration with Refraime, an AI-powered video analytics platform designed to elevate CCTV surveillance through real-time object detection and intelligent alerting.

Read more...
SA’s private security industry receives multi-million USD investment
News & Events Security Services & Risk Management
South Africa's private security sector has attracted significant international attention, with the world’s largest tactical flashlight manufacturer, Nextorch, announcing a major investment in its local operations, Nextorch Africa.

Read more...
Keenfinity launches Radionix as new intrusion brand
Perimeter Security, Alarms & Intruder Detection News & Events
Keenfinity Group’s Intrusion & Access Business Unit has launched Radionix as its new brand for intrusion alarm systems, unlocking new potential and growth opportunities.

Read more...
View from the trenches
Technews Publishing SMART Security Solutions Editor's Choice Integrated Solutions Security Services & Risk Management Residential Estate (Industry)
There are many great options available to estates for effectively managing their security and operations, but those in the trenches are often limited by body corporate/HOA budget restrictions and misunderstandings.

Read more...
The first choice for electric fence management
Stafix Perimeter Security, Alarms & Intruder Detection Residential Estate (Industry) Products & Solutions
In South Africa, over 500 housing estates use JVA Perimeter Patrol, making it a widely used Electric Fence Management providing seamless integration with alarms, CCTV, VMS, access control and control room third-party software.

Read more...
New JVA MBxL energiser range
Stafix Perimeter Security, Alarms & Intruder Detection Residential Estate (Industry) Products & Solutions
The latest MBxL energisers stand out for their simplicity, allowing you to push the “On” button and have the unit tick away, or to configure it through our virtual keypad (VKP).

Read more...
Smart protection for modern living
Products & Solutions Perimeter Security, Alarms & Intruder Detection Residential Estate (Industry)
Recognised globally for their performance and sleek design, AJAX solutions combine professional-grade security with user-friendly control, making them ideal for both residential and commercial environments.

Read more...
IVA AI Pro Visual Gun Detection
Products & Solutions Surveillance Security Services & Risk Management Residential Estate (Industry)
Bosch has announced the launch of the IVA AI Pro Visual Gun Detection analytics based on deep learning. It is designed for automatic detection and classification of people and brandished firearms.

Read more...
IP-based horn loudspeakers
Products & Solutions Surveillance Security Services & Risk Management Residential Estate (Industry)
Bosch has announced the launch of its new IP-based horn loudspeakers and amplifier module: the high-output LHN-UC15L-SIP horn (for long-throw applications), the compact LHN-UC15W-SIP horn (for wide-angle coverage) and the AMN-P15-SIP amplifier module.

Read more...










While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd. | All Rights Reserved.