There are various types of detectors available for fire detection system designers and each type is suitable for a particular use. The type of fire / smoke being detected will determine the choice of detector. Section 8.14 of SANS 10139 gives a guide on selection criteria and factors to consider when carrying out a design.

Below are the various types of detectors available.

1. Point smoke detectors

These detectors use one (or both) of two principles below:

A) Ionisation Chamber Smoke Detectors. This type detects smoke by change in current flows between electrode when smoke enters the chamber of an ionisation detector. This detector is particularly sensitive to smoke containing small particles, such as are produced in rapidly burning flaming fires, but may be less sensitive to the larger particles found in optically dense smoke of similar mass, such as can result from smouldering fires, including those involving polyurethane foam, or overheated PVC. The ionisation detectors contain a small radioactive element that exists in the detection chamber. This has led to most manufacturers stopping the production of these devices. Stringent procedures need to be followed when disposing of this type of detector, which ends up being a costly process.

B) Optical smoke detectors. This type detects smoke by means of the light scatter principle. When smoke enters the chamber the small LED light source within the detector is deflected towards the receiver to trigger the detector. Optical smoke detectors are sensitive to optically dense smoke, but are less sensitive to the small particles found in clean-burning fires that produce little visible smoke.

2. Multisensor fire detectors

This type of detector contains more than one sensor, each of which responds to a different physical and/or chemical characteristic of fire. The purpose of combining sensors in this way is to enhance the performance of the system in detection of fire by means of smoke, heat or CO gasses. These detectors can reduce certain categories of false alarm.

3. Point heat detector

There are two types of point heat detectors. The first type is the Rate of Rise heat detector which reacts to abnormally high rates of temperature change and provides the fastest response over a wide range of ambient temperatures. A fixed temperature limit is also incorporated in these detectors. The second type is the Fixed Temperature which reacts to a pre-determined fixed temperature rather than a rate of rise temperature. The fixed type is suitable where a sudden large change in temperature is considered normal for example in boiler rooms and kitchens.

4. Linear heat detector

Heat detector.
Heat detector.

This type comes in the form of a length of wire or tube. Ideally suitable for cable tunnels, cable trays, transformer bays, etc. There are two types of linear heat detectors:

A) The non–integrating type consists of an electric cable with an insulation of fixed melting point which is suspended over the area to be protected. The melting of the insulation when there is a fire causes a short circuit which causes the system to go into alarm mode.

B) The integrating type is similar to the non-integrating except in this type the insulation does not melt but electrical resistance is temperature dependent. The average temperature is taken over the whole length of wire rather than sections of it.

5. Optical beam detector

Beam detector.
Beam detector.

The optical beam consists of two units, a transmitter and a receiver which can either be two separate units installed at some distance apart or combined into a single unit, and a reflector used to reflect the transmitted beam back to the receiver. Optical beam smoke detectors can prove economical and effective for the protection of large, open plan spaces with relatively high ceilings (e.g. warehouses), particularly if access to point smoke detectors for maintenance could present practical difficulties. It is, however, essential that they be mounted to solid construction that is unlikely to flex as a result of changes in temperature or imposed load, as this can cause mis-alignment of the optical beam and, hence, fault signals or false alarms.

6. Aspirating detectors

This type comprises of a small pump which draws samples of the room air through holes in the system pipework into a detector element. This detector is usually up to 100 times more sensitive than that of conventional point and line type detectors. Aspirating smoke detectors are highly sensitive and can detect smoke even before it is visible to the human eye.

7. Flame detectors

These come in basically two types; infrared flame detectors and ultraviolet flame Detectors. Infrared flame detectors operate by detecting certain frequencies of flicker produced by flaming fires. They are sometimes used to protect very high spaces, such as cathedrals or atria. The detectors do not need to be ceiling mounted; they can be mounted at relatively low levels on walls around a very high protected space, within which only a very large fire could be detected by ceiling mounted heat or smoke detectors. Ultraviolet flame detectors are not generally suitable for this application, since ultraviolet radiation is greatly attenuated by smoke whereas infra-red radiation penetrates smoke well.

8. Carbon monoxide detectors

This type of detector goes into an alarm when they sense a certain amount of carbon monoxide in the air over time. Different types of alarms are triggered by different types of sensors. Carbon monoxide detectors can be immune to certain environmental influences that can result in false alarms from certain smoke detection systems, such as dust, steam and cigarette smoke, while responding to many types of fire appreciably faster than heat detectors.

9. Duct probe unit

This detector is designed to be used where standard smoke, heat and flame types cannot be utilised. It detects the presence of smoke or combustion in extract ventilation ducting systems. Operation is similar to aspirating detectors but it does not contain a pump, it operates on the venturi effect in the sampling pipe providing optimum airflow through the smoke detector.

Choice of detector

Selecting the correct detector for the application is based on several factors, including:

a) The speed of fire detection required, based on an assessment of fire risk.

b) The nature and quantity of the combustible materials present, including ease of ignition, heat release rate, likely form of combustion (e.g. smouldering or flaming) and propensity for smoke production.

c) Probable rate of fire growth and spread.

d) The nature of the environment (e.g. humidity, temperature, cleanliness, extent of pollutants and nature of work processes).

e) The proposed fire evacuation strategy.

f) The height and geometry of the protected area.

g) The attendance time of the fire service (particularly in the case of Category P systems).

h) Other active and passive fire protection measures present.

i) The susceptibility of contents to heat, smoke and water.

j) The speed of response to fire, and the probable false alarm rates, of different types of fire detector.

The Fire Detection Installers Association (FDIA) recommends employing an FDIA contractor for the installation and maintenance of fire detection and gaseous suppression systems.

Contact the FDIA at [email protected] or www.fdia.co.za





Share this article:
Share via emailShare via LinkedInPrint this page



Further reading:

AI-enabled tools reducing time to value and enhancing application security
Editor's Choice
Next-generation AI tools are adding new layers of intelligent testing, audit, security, and assurance to the application development lifecycle, reducing risk, and improving time to value while augmenting the overall security posture.

Read more...
2024 State of Security Report
Editor's Choice
Mobile IDs, MFA and sustainability emerge as top trends in HID Global’s 2024 State of Security Report, with artificial intelligence appearing in the conversation for the first time.

Read more...
Cyberthreats facing SMBs
Editor's Choice
Data and credential theft malware were the top two threats against SMBs in 2023, accounting for nearly 50% of all malware targeting this market segment. Ransomware is still the biggest threat.

Read more...
Are we our own worst enemy?
Editor's Choice
Sonja de Klerk believes the day-to-day issues we face can serve as opportunities for personal growth and empowerment, enabling us to contribute to creating a better and safer environment for ourselves and South Africa.

Read more...
How to spot a cyberattack if you are not a security pro
Editor's Choice
Cybersecurity awareness is straightforward if you know what to look for; vigilance and knowledge are our most potent weapons and the good news is that anyone can grasp the basics and spot suspicious activities.

Read more...
Protecting IP and secret data in the age of AI
Editor's Choice
The promise of artificial intelligence (AI) is a source of near-continuous hype for South Africans. However, for enterprises implementing AI solutions, there are some important considerations regarding their intellectual property (IP) and secret data.

Read more...
Super election year increases risks of political violence
Editor's Choice
Widening polarisation is expected in many elections, with terrorism, civil unrest, and environmental activism risks intensifying in a volatile geopolitical environment. Multinational businesses show an increasing interest in political violence insurance coverage in mitigation.

Read more...
Enhance control rooms with surveillance and intelligence
Leaderware Editor's Choice Surveillance Mining (Industry)
Dr Craig Donald advocates the use of intelligence and smart surveillance to assist control rooms in dealing with the challenges of the size and dispersed nature common in all mining environments.

Read more...
A long career in mining security
Technews Publishing Editor's Choice Security Services & Risk Management Mining (Industry)
Nash Lutchman recently retired from a security and law enforcement career, initially as a police officer, and for the past 16 years as a leader of risk and security operations in the mining industry.

Read more...
A constant armed struggle
Technews Publishing XtraVision Editor's Choice Integrated Solutions Mining (Industry) IoT & Automation
SMART Security Solutions asked a few people involved in servicing mines to join us for a virtual round table and give us their insights into mine security today. A podcast of the discussion will be released shortly-stay tuned.

Read more...