Gas discharge tubes

9 April 2003 Circuit & System Protection Information Security

Gas discharge tube components are made of two or three electrodes in an enclosure filled with a (non-radioactive) rare gas at a controlled pressure. The enclosure is a ceramic tube with its ends closed off by metal caps that also serve as electrodes. Their main use is to protect telecommunications lines.

Operation

The gas discharge tube may be regarded as a very fast switch, having conductance properties that change very rapidly, when breakdown occurs, from open-circuit to quasi-short circuit (arc voltage about 20 V). There are accordingly four operating domains in the behaviour of a gas discharge tube:

* Non-operating domain: characterised by practically infinite insulation resistance.

* Glow domain: at breakdown, the conductance increases suddenly; if the current drained off by the gas tube is less than about 0,5 A (this is a rough value that differs according to the type of component), the glow voltage across the terminals will be in the 80-100 V range.

* Arc regime: as the current increases, the gas discharge tube shifts from the glow voltage to the arc voltage (20 V). It is in this domain that the gas discharge tube is most effective, because the current discharged can reach several thousand amperes without the arc voltage across its terminals increasing.

* Extinction: at a bias voltage roughly equal to the glow voltage, the gas tube recovers its initial insulating properties.

Operating areas
Operating areas

Electrical characteristics

DC sparkover voltage

This is the main characteristic defining the gas discharge tube. It is the voltage at which breakdown will occur between the electrodes when a slowly increasing voltage (dV/dt = 100 V/s) is applied to the component; it depends on the electrode spacing, the pressure, and the properties of the gas mixture and of the emissive substance.

The range of DC sparkover voltages available are: minimum 25 V; average 230 V; high voltage 500 V; and very high voltage 1000 to 3000 V. (The tolerance on the breakdown voltage is generally ±20%.)

Discharge current

This depends on the properties of the gas, the volume, and the material and treatment of the electrodes. It is the major characteristic of the gas discharge tube and the one that distinguishes it from other protection devices (Varistor, Zener diode, etc.): 5 to 20 kA with an 8/20 µs impulse for the standard components. This is the value the device can withstand repeatedly (say for 10 impulses) without destruction or alteration of its basic specifications.

Impulse sparkover voltage

Sparkover voltage is the presence of a steep rise front (dV/dt = 1 kV/µs); the impulse sparkover voltage increases with increasing dV/dt.

DC and impulse sparkover voltages
DC and impulse sparkover voltages

Insulation resistance and capacitance

These characteristics make the gas discharge tube practically 'invisible' in a line in a steady-state context: insulation resistance very high (1 GΩ), capacitance very low (<10 pF).

3-electrode configurations

Protecting a two-wire line (for example a telephone pair) with two 2-electrode gas discharge tubes (connected between the wires and ground) may cause the following problem: the line is subjected to an overvoltage in common mode; because of the dispersion of the sparkover voltages (±20%), one of the gas discharge tubes sparks over a very short time before the other (a few microseconds); the wire that has sparked over is therefore grounded (neglecting the arc voltages), turning the common-mode overvoltage into a differential-mode overvoltage - very dangerous for the terminal equipment. This risk disappears when the second gas discharge tube arcs over (a few microseconds later).

3-electrode geometry eliminates this drawback; the sparkover of one pole causes a 'general' breakdown of the device almost instantaneously (a few nanoseconds) because there is only one gas-filled enclosure.

3-electrode gas discharge tube
3-electrode gas discharge tube

End of life

Gas discharge tubes are designed to withstand several impulses without destruction or loss of the initial characteristics (typical impulse tests: 10 times 5 kA impulses of each polarity). On the other hand, a sustained strong current (eg, 10 A r.m.s. for 15 s, simulating the fall of a power line onto a telecommunications line) will put the device out of service indefinitely.

If a failsafe end of life is desired (ie, a short-circuit that will report the fault to the user when the line fault is detected), gas discharge tubes with the failsafe feature (external short-circuit) should be chosen.

The Citel line

Citel offers a line of gas discharge tubes, certified radioactive-free, to meet most configuration needs and specifications found on the market:

*p 2 and 3-electrode gas discharge tubes.

* Sparkover voltages from 75 to 3000 V.

* Discharge capacities from 2,5 to 150 kA.

* Optional external short-circuit device.

* Installation on support, on printed circuit, or surface-mounted devices.

They comply with the specifications of most telecom operators and with the ITU-K12 international recommendation.





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Clearing the Static: Understanding the significance of ESD audits
Actum Electronics Circuit & System Protection
An ESD (Electrostatic Discharge) audit is the first step in establishing an ESD plan, and it is important to include all areas where ESD-sensitive components are being handled.

Read more...
Microchip introduces ECC608 TrustMANAGER
Altron Arrow Circuit & System Protection
To increase security on IoT products and facilitate easier setup and management, Microchip Technology has added the ECC608 TrustMANAGER with Kudelski IoT keySTREAM, Software as a Service (SaaS) to its Trust Platform portfolio of devices, services and tools.

Read more...
Varistors for automotive applications
Future Electronics Circuit & System Protection
TDK Corporation has announced the addition of two new varistors to its AVRH series for automotive applications where both are characterised by the high electrostatic discharge-withstanding voltage demanded to ensure the safe operation of safety-critical automotive functions.

Read more...
Clearing the Static: The importance of ESD wrist straps
Actum Electronics Circuit & System Protection
ESD clothing plays a pivotal role in preventing that people do not charge the products that they are working with.

Read more...
Data security and privacy in global mobility
Security Services & Risk Management Information Security
Data security and privacy in today’s interconnected world is of paramount importance. In the realm of global mobility, where individuals and organisations traverse borders for various reasons, safeguarding sensitive information becomes an even more critical imperative.

Read more...
Sophos celebrates partners and cybersecurity innovation at annual conference
News & Events Information Security
[Sponsored] Sun City hosted Sophos' annual partner event this year, which took place from 12 to 14 March. Sophos’ South African cybersecurity distributors and resellers gathered for an engaging two-day conference.

Read more...
The CIPC hack has potentially serious consequences
Editor's Choice Information Security
A cyber breach at the South African Companies and Intellectual Property Commission (CIPC) has put millions of companies at risk. The organisation holds a vast database of registration details, including sensitive data like ID numbers, addresses, and contact information.

Read more...
Clearing the Static: ESD clothing and footwear
Actum Electronics Circuit & System Protection
ESD clothing plays a pivotal role in preventing that people do not charge the products that they are working with.

Read more...
AI augmentation in security software and the resistance to IT
Security Services & Risk Management Information Security
The integration of AI technology into security software has been met with resistance. In this, the first in a series of two articles, Paul Meyer explores the challenges and obstacles that must be overcome to empower AI-enabled, human-centric decision-making.

Read more...
Milestone Systems joins CVE programme
Milestone Systems News & Events Information Security
Milestone Systems has partnered with the Common Vulnerability and Exposures (CVE) Programme as a CVE Numbering Authority (CNA), to assist the programme to find, describe, and catalogue known cybersecurity issues.

Read more...